<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-27 01-31-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.00 MHz 4/5, 60 dBuV R F I
Pilot RDS Phase Difference
7.6 kHz 4.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
15 kHz 49 kHz 6998 0,1000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
1,2 dBr 1,84 dBr 2,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" R F I " FE10 0 (No PTY) 0 0 0 1 1:31, 27.01.2025
RT
"LITTERATURE SANS FRONTIERES "
AF EON
89.0 MHz -
FM Scope Station: 89.00 MHz, signal: 4/5 (61 dBuV) Max at: 49 kHz MIN: 15 kHz % above 75 kHz: 0,1000 Acquired: 2025/01/27 1:30:44 Total samples: 6998 Equivalent time: 0:05:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 2,6 dBr MIN: 1,2 dBr AVE: 1,84 dBr % above 10,0 dBr: 0,0 Last value: 2,1 dBr (2025/01/27 1:30:43) Station: 89.00 MHz, signal: 4/5 (61 dBuV) 01:24 01:25 01:26 01:27 01:28 01:29 01:30 0 50 100 Dev. MAX [kHz] 0 2 Pm [dBr] 0 5 Signal Quality